APPLICATION CONCEPT | AUTOMOTIVE COATING
CUSTOM INDUSTRIAL INFRARED HEATING
PUBLIC CONFIGURATION REFERENCE
A fast-response medium-wave tunnel adds radiant energy to the coated bumper surface.
Reference data subject to application testing and specification review.
A paint line may need more pre-drying capacity before the main convection oven but have limited floor space for another large thermal section.
A fast-response medium-wave tunnel adds radiant energy to the coated bumper surface. Three optical pyrometers help manage different part contours.
COAT
Apply basecoat
FLASH
Release solvent
IR BOOST
Pre-dry surface
OVEN
Complete the schedule
REFERENCE SCALE
19 x 3 kW emitters; 57 kW total
SENSING
Three optical pyrometers
EMITTER
Fast-response medium-wave infrared
CONTROL
Conveyor, part detect and temperature
CUSTOM DESIGN
Tunnel, profile zones and ventilation
CONFIRM
Basecoat, solvent, part color and speed
APPLICATION NOTE
Public case-study configuration reference - not a YFR performance claim. Final ratings and results require YFR sample testing and engineering confirmation.
Need a heating solution for this process?
Share your dimensions, target temperature and cycle time with YFR.